Switch Operration And Taping
1.Use Tweezers or ball point pen for operation.
*Keep all actuators in"OFF"position during soldering and cleaning process.
*Any flxu enters the switch may influence contat function.
Features
1.All materials are UL94V0 grade ,temperature resistancd plastic.
2.Gold-plated contact to ensure low contact resistance Tin plated teminals to prevent contamination during soldering.
Material
Part Name
|
Material
|
Finished
|
Base
|
UL94V0
|
Black
|
Cover
|
UL94V0
|
Red
|
Actuator
|
UL94V0
|
White
|
Tetminal
|
Brass
|
Gold/Tin
|
Tetminal
|
Brass
|
Gold/Tin
|
Ratings
Contact Rating
|
Switching
|
25mA at 24VDC
|
Contact Resistance
|
Non-Switching
|
100mA at 50VDC
|
lnital
|
50mΩ Max.
|
Contact Resistance
|
After life
|
100mΩ Max.
|
lnsulation Resistance
|
100mΩ Min.60sec at 500VDC
|
Dlelectric Strength
|
500V DC for 60 seconds
|
Switch Capacitance
|
5pF Max.at 1M Hz
|
Operation Temperature
|
-40℃ ~+85℃
|
Storage Temperature
|
-40℃ ~+85℃
|
Mechanical & Processing
|
Operation Force
|
1000gf Max.
|
Electrical Life
|
3000 cycles 25mA 24VDC
|
Order informati
Dimensions(unit:mm)
Gold/Gold Platedg Type P/N
|
Dimensions mm(inch)
|
Quantity per Tube
|
A
|
B
|
UWH- HL01GBKT
|
4.03(0.16)
|
/
|
|
UWH- HL02GBKT
|
5.57(0.22)
|
2.54(0.1)
|
70
|
UWH- HL03GBKT
|
9.11(0.36)
|
5.08(0.2)
|
50
|
UWH- HL04GBKT
|
11.65(0.46)
|
7.62(0.3)
|
40
|
UWH- HL05GBKT
|
14.19(0.56)
|
10.16(0.4)
|
33
|
UWH- HL06GBKT
|
16.73(0.66)
|
12.70(0.5)
|
28
|
UWH- HL07GBKT
|
19.27(0.76)
|
15.24(0.6)
|
24
|
UWH- HL08GBKT
|
21.87(0.86)
|
17.70(0.7)
|
21
|
UWH- HL09GBKT
|
24.35(0.96)
|
20.32(0.8)
|
19
|
UWH- HL10GBKT
|
26.89(1.06)
|
22.86(0.9)
|
17
|
UWH- HL12GBKT
|
31.97(1.26)
|
27.94(1.1)
|
12
|
Environmental test
Cold Resistance Test
|
Switches under temperature at-40℃ ±2℃ for 96 hours
|
Dry Heat Resistance Test
|
Switches under temperature at 85℃ ±2℃ for 96 hours
|
Humidity Test
|
Per MIL-STD-202F, Method 103B,Test Condition B
|
There shallbe on evidence of corrosion and the insulation resistance shall be no less than100 megaohms
|
Vibration Test
|
Per MIL-STD-202F, Method 204D,Test Condition A
|
there shall be no opening of closed contacts or closing of open contacts in excess of 10 micoseconds
|
Shock Test
|
Per MIL-STD-202F, Method 213B,Test Condition A
|
There shall be no opening of closed contacts or closing of open contacts in excess iof 10mincrosedconds
|
Thermal Shock Test
|
Per MIL-STD-202F, Method 107G,Test Condition A
|
There shall be no evidence of physical damage of permanent change in electrical characteristics
|
Salt-spray Test
|
Per MIL-STD-202F, Method 101D,Test Condition B
|
There are under 35±2℃ in temperature and 5±1% salt-water concentration for 48±1hour
|
Dragram