PRODUCT
Category
Contact Us

UTILITY Electrical Co., Ltd

ADD: 1759 Zhongshan North Road, Shanghai Pudong Development Plaza D2301 Room, 200061

ZIP:200061

TEL:+86-021-6147 8345

FAX:+86-021-6147 8346

EMAIL:marketing@china-utl.com

Learn more >>
Products
大

Print

Collection folder

Email: marketing@china-utl.com

Fax: +86-021-6147 8346

Tel:+86-021-6147 8345

Switch Operration And Taping
1.Use Tweezers or ball point pen for operation.
*Keep all actuators in"OFF"position during soldering and cleaning process.
*Any flxu enters the switch may influence contat function.
Features
1.All materials are UL94V0 grade ,temperature resistancd plastic.
2.Gold-plated contact to ensure low contact resistance Tin plated teminals to prevent contamination during soldering.
Material

Part Name

Material

Finished

Base

UL94V0

Black

Cover

UL94V0

Red

Actuator

UL94V0

White

Tetminal

Brass

Gold/Tin

Tetminal

Brass

Gold/Tin

Ratings

Contact Rating

Switching

25mA at 24VDC

Contact Resistance

Non-Switching

100mA at 50VDC

lnital

50mΩ Max.

Contact Resistance

After life

100mΩ Max.

lnsulation Resistance

100mΩ Min.60sec at 500VDC

Dlelectric Strength

500V DC for 60 seconds

Switch Capacitance

5pF Max.at 1M Hz

Operation Temperature

-40℃ ~+85℃

Storage Temperature

-40℃ ~+85℃

Mechanical & Processing

Operation Force

1000gf Max.

Electrical Life

3000 cycles 25mA 24VDC

Order informati

 

Dimensions(unit:mm)

Gold/Gold Platedg Type P/N

Dimensions mm(inch)

Quantity per Tube

A

B

UWH- HL01GBKT

4.03(0.16)

/

 

UWH- HL02GBKT

5.57(0.22)

2.54(0.1)

70

UWH- HL03GBKT

9.11(0.36)

5.08(0.2)

50

UWH- HL04GBKT

11.65(0.46)

7.62(0.3)

40

UWH- HL05GBKT

14.19(0.56)

10.16(0.4)

33

UWH- HL06GBKT

16.73(0.66)

12.70(0.5)

28

UWH- HL07GBKT

19.27(0.76)

15.24(0.6)

24

UWH- HL08GBKT

21.87(0.86)

17.70(0.7)

21

UWH- HL09GBKT

24.35(0.96)

20.32(0.8)

19

UWH- HL10GBKT

26.89(1.06)

22.86(0.9)

17

UWH- HL12GBKT

31.97(1.26)

27.94(1.1)

12

Environmental test

Cold Resistance Test

Switches under temperature at-40℃ ±2℃ for 96 hours

Dry Heat Resistance Test

Switches under temperature at 85℃ ±2℃ for 96 hours

Humidity Test

Per MIL-STD-202F, Method 103B,Test Condition B
There shallbe on evidence of corrosion and the insulation resistance shall be no less than100 megaohms

Vibration Test

Per MIL-STD-202F, Method 204D,Test Condition A
there shall be no opening of closed contacts or closing of open contacts in excess of 10 micoseconds

Shock Test

Per MIL-STD-202F, Method 213B,Test Condition A
There shall be no opening of closed contacts or closing of open contacts in excess iof 10mincrosedconds

Thermal Shock Test

Per MIL-STD-202F, Method 107G,Test Condition A
There shall be no evidence of physical damage of permanent change in electrical characteristics

Salt-spray Test

Per MIL-STD-202F, Method 101D,Test Condition B
There are under 35±2℃ in temperature and 5±1% salt-water concentration for 48±1hour
Dragram